- Страна происхождения
- Литва
- Тип датчика
- Датчик линейных перемещений
- Длина измерения
- от 140 до 3240 мм
- Метод измерения
- Инкрементальный

OUTPUT SIGNALS AND RESOLUTION: |
MEASURING LENGTH: |
REFERENCE MARKS: |
ACCURACY: | SUPPLY VOLTAGE: |
CABLE OR CONNECTOR OUTLET: |
CABLE LENGTH: | CONNECTOR TYPE: |
A - Sinusoidal AV - Sinusoidal F01 - TTL / HTL 0.1µm F02 - TTL / HTL 0.2µm F05 - TTL / HTL 0.5µm F10 - TTL / HTL 1.0µm F25 - TTL / HTL 2.5µm F50 - TTL / HTL 5.0µm |
0070 - 70mm 0520 - 520mm ... 3240 - 3240mm |
N - none RI S - standard M - every 50mm K - distance-coded Ln/XXX - n´RI with 50- fold steps /XXX distance of the frst RI from the beginning of ML, mm O - selection by magnets (standard - one magnet (RI) in ML middle) |
10 - ±10µm 05 - ±5µm 03 - ±3µm (optional) |
05V - +5V 12V - +12V* *only for L37-F |
S - version S (cable outlet) C - version C (con nector outlet) |
01 - 1m 02 - 2m 03 - 3m ... CP01- 1m armoured CP02 - 2m armoured CP03 - 3m armoured ... |
W - without connector C9 -round, 9 pins C12 - round, 12 pins D9 - flat, 9 pins D15 - flat, 15 pins |
ORDER EXAMPLE: | 1) L37-F05-2040-O-10-05V-C-CP03/C12 |
L37 | - | XXX | - | XXXX | - | X | / | XXX | - | XX | - | XX | - | X | - | XX | / | X |
Version | L37-A 11µApp | L37-AV 1Vpp | L37-F TTL (HTL on request) |
Supply voltage | + 5 V ± 5 % / < 90 mA | + 5 V ± 5 % / < 120 mA | + 5 V ± 5 % / < 120 mA; + 12 V ±5% / < 130 mA |
Light source | LED | LED | LED |
Resolution | Depends on external subdividing electronics |
Depends on external subdividing electronics |
5; 2.5; 1; 0.5; 0.2; 0.1 μm (after 4 - fold dividing in subsequent electronics) |
Incremental signals |
Two sinusoidal I1 and I2 |
Differential sine +A / -A and +B / -B Amplitude at 120 kΩ load: - A = 0.6 - 1.2 V - B = 0.6 - 1.2 V |
Differential square-wave U1 / U1and U2 / U2. Signal levels at 20 mA load current: |
Reference signal |
One quasi-triangular I0 peek per revolution. Signal magnitude at 1 kΩ load: |
One quasi-triangular +R and its complementary -R per revolution. Signals magnitude at 120 Ω load: |
One differential square-wave U0 / U0 per revolution. Signal levels at 20 mA load current: |
Maximum operating frequency |
50 kHz (v=1 m/s) |
50 kHz (v=1 m/s) |
(50xk) kHz for k = 1, 2, 5, 10 100 kHz for k = 25, 50 |
Direction of signals (displacement from left to right) | I2 lags I |
+ B lags + A |
U2 lags U1 (displacement from left to right and head position down respective glass scale) |
Standard cable length | 3 m; without connector | 3 m; without connector | 3 m; without connector |
Maximum cable length | 5 m | 25 m | 25 m |
Нужна консультация?
Вы можете связаться с нами по номеру телефона либо оставить заявку и мы свяжемся с вами в течении 10 минут...