- Страна происхождения
- Литва
- Тип датчика
- Датчик линейных перемещений
- Длина измерения
- от 70 до 1240 мм
- Метод измерения
- Инкрементальный
OUTPUT SIGNALS AND RESOLUTION: |
MEASURING LENGTH: |
REFERENCE MARKS: |
ACCURACY: | CABLE OR CONNECTOR OUTLET: |
CABLE LENGTH: |
CONNECTOR TYPE: |
A - Sinusoidal AV - Sinusoidal F01 - TTL 0.1µm F02 - TTL 0.2µm F05 - TTL 0.5µm F10 - TTL 1.0µm F25 - TTL 2.5µm F50 - TTL 5.0µm |
0070 - 70 mm 0520 - 520 mm .... 1240 - 1240 mm |
N - none RI S - standard M - every 50 mm K - distance coded Ln/XXX - n´RI with 50-fold steps /XXX distance of the frst RI from the beginning of ML, mm |
05 - ±5 µm 10 - ±10 µm |
S - version S (cable outlet) C - version C (connector outlet) |
01 - 1m 02 - 2m 03 - 3m ... CP01 - 1m armoured CP02 - 2m armoured CP03 - 3m armoured ... |
W - without connector B12 - round, 12 pins C9 -round, 9 pins C12 - round, 12 pins D9 - flat, 9 pins D15 - flat, 15 pins RS10 - round, 10 pins ONC - round, 10 pins |
ORDER EXAMPLE: | 1) L18T-A-1240-K-05-C-03/C9 |
L18T | - | XXX | - | XXXX | - | X | / | XXX | - | XX | - | X | - | XX / X |
Version | L18T-A ∫ 11 µApp | L18T-AV ∫ 1 Vpp | L18T-F Π TTL |
Supply voltage | + 5 V ± 5 % / < 90 mA | + 5 V ± 5 % / < 120 mA | + 5 V ± 5 % / < 120 mA |
Light source | LED | LED | LED |
Resolution |
Depends on external subdividing electronics |
Depends on external subdividing electronics |
5; 1; 2.5; 0.5; 0.2; 0.1 µm (after 4 - fold dividing in subsequent electronics) |
Incremental signals |
Two sinusoidal I1 and I2 |
Differential sine +A / -A and +B / -B Amplitude at 120 kΩ load: - A = 0.6 - 1.2 V - B = 0.6 - 1.2 V |
Differential square-wave U1 / U1and U2 / U2. Signal levels at 20 mA load current: |
Reference signal |
One quasi-triangular I0 peek per revolution. Signal magnitude at 1 kW load: |
One quasi-triangular +R and its complementary -R per revolution. Signals magnitude at 120 W load: |
One differential square-wave U0 / U0 per revolution. Signal levels at 20 mA load current: |
Maximum operating frequency |
50 kHz |
50 kHz |
50xk kHz, when interpolation factor is 1,2,5,10 1000 kHz, when interpolation factor is 25, 50 |
Direction of signals | I2 lags I1 at reading head displacement from left to right | + B lags + A at reading head displacement from left to right | U2 lags with U1 at reading head displacement from left to right |
Standard cable length | 3 m; without connector | 3 m; without connector | 3 m; without connector |
Maximum cable length | 5 m | 25 m | 25 m |
Нужна консультация?
Вы можете связаться с нами по номеру телефона либо оставить заявку и мы свяжемся с вами в течении 30 минут...